5-37
Fault code
J1939 SPN
J1939 FMI
Reason
Effect (only when fault code is active)
2373
1209
3
Exhaust gas pressure sensor circuit - Voltage
above normal or shorted to high source. High
signal voltage detected at the exhaust gas
pressure circuit.
Possible reduced engine performance.
2374
1209
4
Exhaust gas pressure sensor circuit - Voltage
below normal or shorted to low source. Low
signal voltage detected at the exhaust gas
pressure circuit.
Possible reduced engine performance.
2375
412
3
Exhaust gas recirculation temperature sensor
circuit - Voltage above normal or shorted to
high source. High signal voltage detected at
EGR temperature circuit.
Possible reduced engine performance.
2376
412
4
Exhaust gas recirculation temperature sensor
circuit - Voltage below normal or shorted to low
source. Low signal voltage detected at EGR
temperature circuit.
Possible reduced engine performance.
2377
647
3
Fan control circuit - Voltage above normal, or
shorted to high source. Open circuit or high
voltage detected at the fan control circuit.
The fan can stay on continuously or not run at
all.
2387
641
7
VGT Actuator driver circuit (motor) - Mechanical
system not responding or out of adjustment.
The smar t VGT controller has detected
incorrect stop limits, or the VGT is unable to
move to the closed position.
Possible reduced engine performance.
2398
171
2
Ambient air temperature - Data erratic,
intermittent, or incorrect. The ambient air
temperature sensor is reading an erratic value.
Possible reduced engine performance.
2448
111
17
Coolant level - Data valid but below normal
operational range - Least severe level. Low
engine coolant level detected.
none on performance.
2449
641
13
Vgt actuator controller - Out of calibration.
T h e VG T a c t u a t o r h a s b e e n i n s t a l l e d
incorrectly.
Possible reduced engine performance.
2468
102
3
Engine crankshaft speed/position - Data valid
but above normal operating range - Moderately
severe level. The engine speed has exceeded
a critical limit.
Engine will be shut down.
2554
1209
2
E x h a u s t g a s p r e s s u r e - D a t a e r ra t i c,
intermittent or incorrect. The exhaust gas
pressure sensor is reading an erratic value.
possible reduced engine performance.
2555
729
3
Intake air heater 1 circuit - Voltage above
normal, or shorted to high source. High voltage
detected at the intake air heater signal circuit.
The intake air heaters may be ON or OFF all
the time.
2556
729
4
Intake air heater 1 circuit - Voltage below
normal, or shorted to low source. Low voltage
detected at the intake air heater signal circuit.
The intake air heaters may be ON or OFF all
the time.
2634
641
12
VGT Actuator controller - Bad intelligent device
or component. An internal error has been
detected by the smart VGT controller.
Possible reduced engine performance.
侍#