5-22
5-22
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
135
0
10 seconds continuous, Swing Pilot Press. Sensor
Measurement Voltage > 5.2V
侑
1
10 seconds continuous, 0.3V
≤
Swing Pilot Press. Sensor Measurement
Voltage < 0.8V
侑
4
10 seconds continuous, Swing Pilot Press. Sensor
Measurement Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Swing Pilot Press. display failure
2. Control Function – IPC operation, Boom first operation failure
(Checking list)
1. CD-24 (#B) – CN-52 (#36) Checking Open/Short
2. CD-24 (#A) – CN-51 (#3) Checking Open/Short
3. CD-24 (#C) – CN-51 (#13) Checking Open/Short
138
0
Monitor – Select Attachment(breaker / crusher)
10 seconds continuous, Attachment Pilot Press. Sensor Measurement
Voltage > 5.2V
侑
1
Monitor – Select Attachment(breaker / crusher)
10 seconds continuous, 0.3V
≤
Attachment Pilot Press. Sensor
Measurement Voltage < 0.8V
侑
4
Monitor – Select Attachment(breaker / crusher)
10 seconds continuous, Attachment Pilot Press. Sensor Measurement
Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Attachment Pilot Press. display failure
2. Control Function – Option attachment flow control operation failure
(Checking list)
1. CD-69 (#B) – CN-53 (#14) Checking Open/Short
2. CD-69 (#A) – CN-53 (#3) Checking Open/Short
3. CD-69 (#C) – CN-53 (#13) Checking Open/Short
139
1
10 seconds continuous, 0.3V
≤
Option Pilot Press. Sensor Measurement
Voltage < 0.8V
侑
4
10 seconds continuous, Option Pilot Press. Sensor
Measurement Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Option Pilot Press. display failure
2. Control Function – Auto Idle operation failure
(Checking list)
1. CD-100 (#B) – CN-52 (#21) Checking Open/Short
2. CD-100 (#A) – CN-51 (#3) Checking Open/Short
3. CD-100 (#C) – CN-1 (#6) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.