5-33
5-22-11
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
222
5
Monitor – Selecting attachment(crusher)
(Detection)
(When ATT Relief Setting EPPR 2 Current is equal or more than 10 mA)
10 seconds continuous, ATT Relief Setting EPPR 2 drive current = 0 mA
(Cancellation)
(When ATT Relief Setting EPPR 2 Current is equal or more than 10 mA)
3 seconds continuous, ATT Relief Setting EPPR 2 drive current
≥
10mA
侑
6
(Detection)
10 seconds continuous, ATT Relief Setting EPPR 2 drive current > 1.0 A
(Cancellation)
3 seconds continuous, ATT Relief Setting EPPR 2 drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – Option attachment flow control – P2 relief pressure setting failure
(Checking list)
1. CD-366 (#2) – CN-53 (#32) Checking Open/Short
2. CD-366 (#1) – CN-53 (#33) Checking Open/Short
301
3
10 seconds continuous, Fuel Level Measurement Voltage > 3.8V
侑
4
10 seconds continuous, Fuel Level Measurement Voltage < 0.3V
侑
(Results / Symptoms)
1. Monitor – Fuel remaining display failure
(Checking list)
1. CD-2 (#2) – CN-52 (#26) Checking Open/Short
2. CD-2 (#1) – CN-51 (#5) Checking Open/Short
325
4
(Model Parameter) mounting Fuel Warmer Relay
(Detection)
(When Fuel Warmer Relay is Off)
10 seconds continuous, Fuel Warmer Relay drive unit
Measurement Voltage
≤
3.0V
(Cancellation)
(When Fuel Warmer Relay is Off)
3 seconds continuous, Fuel Warmer Relay drive unit
Measurement Voltage > 3.0V
侑
6
(Detection)
(When Fuel Warmer Relay is On)
10 seconds continuous, Fuel Warmer Relay drive current > 4.5 A
(Cancellation)
(When Fuel Warmer Relay is On)
3 seconds continuous, Fuel Warmer Relay drive current
≤
4.5 A
侑
(Results / Symptoms)
1. Control Function – Fuel warmer operation failure
(Checking list)
1. CR-46 (#85) – CN-52 (#30) Checking Open/Short
2. CR-46 (#86) – CN-45 (#B+ term) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#