6-30
7. WHEN HYDRAULIC OIL TEMPERATURE WARNING LAMP LIGHTS UP (engine is started)
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
HYDRAULIC OIL
TEMPERATURE SENDER
CD-1
2
1
C
CN-51
MCU
5
CN-52
24
Starting switch : ON
Engine : Start
Does display go
off when
disconnect
CD-1?
Resistance
between CN-51
(5) and CN-52
(24) is 0~1
̫
?
Starting switch : OFF
Disconnect CN-51, 52
Resistance
between CD-1
(1, 2) is in range
of 164~151
̫
?
Starting switch : ON
Disconnect CD-1
YES
YES
YES
NO
NO
NO
300L6ES08
Temperature (˚C ) ~ -30
~ -10
~ 0
~ 40
~ 70
~ 80
~ 90
~ 100
105~
Resistance (k
̫
)
22.22
~31.78
8.16
~10.74
5.18
~ 6.6
1.06
~1.28
0.39
~0.476
0.322
~0.298
0.243
~0.219
0.185
~0.167
0.164
0.151
Check Table
Cause
Remedy
High temperature
Defective temp
sensor
Short circuit
between temp
sensor and MCU
Defective controller
Check hydraulic
system
Replace
Repair or replace
Replace