3-23
3-23
TRAVEL CIRCUIT OPERATION
Valves are provided on travel motors to offer the following functions.
COUNTER BALANCE VALVE
When stopping the motor of slope descending, this valve to prevent the motor over run.
OVERLOAD RELIEF VALVE
Relief valve limit the circuit pressure below 370 kgf/cm
2
(5260 psi) for the travel motor type 1 and 360
kgf/cm
2
(5120 psi) for the travel motor type 2 to prevent high pressure generated at a time of stopping
the machine. Stopping the motor, this valve sucks the oil from lower pressure passage for
preventing the negative pressure and the cavitation of the motor.
1)
2)
380L3HC19