5-72
HEST (High exhaust system temperature) warning lamp
2609A3CD211
(13)
Manual regeneration method of DPF
380F3CD07
侍
This warning lamp indicates, when illuminated, that exhaust
temperatures are high due to regeneration of the DPF.
The lamp will also illuminate during a manual regeneration.
When this lamp is illuminated, be sure the exhaust pipe outlet
is not directed at any surface or material that can melt, burn, or
explode.
When this lamp is illuminated, the exhaust gas temperature
could reach 800˚C [1500˚F], which is hot enough to ignite or
melt common materials, and to burn people.
The lamp does not signify the need for any kind of equipment
or engine service; It merely alerts the equipment operator to
high exhaust temperatures. It will be common for the lamp to
illuminate on and off during normal equipment operation as the
engine completes regeneration.
刮
刯
到
侍
Safety button
1
2
OFF
DPF warning
lamp
OFF
HEST warning
lamp
DPF warning
lamp
HEST warning
lamp
ON
ON
Manual regeneration applies if the machine is in a fireproof
area and there is no plan to turn off the maching during the
regeneration.
Stop and park the machine.
Select user mode and set the engine speed to minimum
speed.
Return to the operation screen.
Pull the safety button and push the switch to position
刯#
to
initiate the manual regeneration of DPF.
Refer to the page 3-36 for the switch operation.
The engine speed may increase to 950~1050 rpm and DPF
regeneration begins and it will take approximately 20~30 min-
utes.
The DPF and HEST warning lamp will light ON during the
regeneration function is operating.
The DPF and/or HEST warning lamp will light OFF when the
regeneration function is completed.
侍
刮
刯
到
刱
侍
侍
刲
刳