4-7
OPERATING FLOW
Battery Battery relay Circuit breaker [CN-60] Master switch [CS-74A]
Fuse box [No.1] Engine ECM [CN-93 (1, 25, 26, 27, 28)]
Fuse box [No.2] DEF supply module [CR-51 (2, 3)]
DEF purging lamp [CL-40 (1)]
Fuse box [No.3] I/conn [CN-5 (59)] I/conn [CN-10 (3)] Room lamp [CL-1 (2)]
Door switch [CS-1]
Radio & USB player [CN-27A (8)]
Fuse box [No.4] MCU [CN-51 (1)]
MCU [CN-52 (8)]
MCU [CN-53 (1, 25)]
Fuse box [No.5] Master switch [CS-74B] l/conn [CN-5 (36)] Start switch [CS-2A (1)]
RMS [CN-125A(1)]
GPS connection [CN-125 (1)]
Power relay [CR-35 (30)]
Fuse box [No.6] l/conn [CN-11 (5)] AC & Heater control box A (7)
Blower relay (4)
Fuse box [No.7] I/conn [CN - 5 (18)] I/conn [CN-17 (5)] Wiper motor controller
[CN-141 (7)]
Wiper motor [CN-21 (4)]
Fuse box [No.8] I/conn [CN - 5 (11)] Cluster [CN-56A (1)]
Hour meter [CN-48 (1)]
I/conn [CN - 8 (6)] Haptic controller [CN-363 (2)]
#
侍
I/conn : Intermediate connector
CHECK POINT
侍#
GND : Ground
1)
2)
1. POWER CIRCUIT
The negative terminal of battery is grounded to the machine chassis.
When the start switch is in the OFF position, the current flows from the positive battery terminal as
shown below.
Engine
Start switch
Check point
Voltage
OFF
OFF
刮
- GND (battery 1EA)
刯
- GND (battery 2EA)
到
- GND (battery relay 2EA)
刱
- GND (circuit breaker)
10~12.5V
20~25V
20~25V
20~25V