6-44
3. MALFUNCTION OF CLUSTER OR MODE SELECTION SYSTEM
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
侍
1)
See if HCESPN
840 active fault
display on the LCD
See if all lamps
off in the MCU
case
Check connection
between CN-51
(22) - CN-56A(6)
or CN-51(32) -
CN-56A(7)
Cause
Remedy
No power supply to
the MCU
MCU failure
刔
Cluster failure
No connection
Check fuse No.4
Replace
Replace
Check and repair
CLUSTER
6
7
CN-56A
6
5
CN-5
CN-51
22
32
MCU
FUSE
NO.4
1
GND
CAN1 HI
IG 24V
BATT.24V
CAN1 LO
CAN2 HI
CAN2 LO
RS-232 RX
RS-232 TX
AUX LEFT
AUX RIGHT
AUX GND
刔
R
Y
G
KEY OFF
Wiring diagram
YES
YES
YES
NO
OK
NO
NO
NO
380L6MS03
G
R
Y
G
R
Y