5-27
5-22-5
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
169
4
Monitor – Selecting attachment(breaker / crusher)
(Detection)
(When Attachment Conflux Solenoid is Off)
10 seconds continuous, Attachment Conflux Solenoid drive unit
Measurement Voltage
≤
3.0V
(Cancellation)
(When Attachment Conflux Solenoid is Off)
3 seconds continuous, Attachment Conflux Solenoid drive unit Measurement
Voltage > 3.0V
侑
6
(Detection)
(When Attachment Conflux Solenoid is On)
10 seconds continuous, Attachment Conflux Solenoid drive Current > 6.5 A
(Cancellation)
(When Attachment Conflux Solenoid is On)
3 seconds continuous, Attachment Conflux Solenoid drive Current
≤
6.5 A
侑
(Results / symptoms)
1. Control Function – Option attachment flow control – Joining operation failure
(Eco breaker mode, crusher mode)
(Checking list)
1. CD-237 (#1) – CN-53 (#7) Checking Open/Short
2. CD-237 (#2) – CR-35 (#87) Checking Open/Short
170
4
(Model Parameter) mounting Arm Regenerating Solenoid
(Detection)
(When Arm Regeneration Solenoid is Off)
10 seconds continuous, Arm Regeneration Solenoid drive unit Measurement
Voltage
≤
3.0V
(Cancellation)
(When Arm Regeneration Solenoid is Off)
3 seconds continuous, Arm Regeneration Solenoid drive unit Measurement
Voltage > 3.0V
侑
6
(Detection)
(When Arm Regeneration Solenoid is On)
10 seconds continuous, Arm Regeneration Solenoid drive current > 4.5 A
(Cancellation)
(When Arm Regeneration Solenoid is On)
3 seconds continuous, Arm Regeneration Solenoid drive current
≤
4.5 A
侑
(Detection)
(When Arm Regeneration Solenoid is On)
10 seconds continuous, Arm Regeneration Solenoid drive current > 4.5 A
(Cancellation)
(When Arm Regeneration Solenoid is On)
3 seconds continuous, Arm Regeneration Solenoid drive current
≤
4.5 A
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.