6-59
11. MALFUNCTION OF ARM IN/OUT & BUCKET IN PRESSURE SENSOR
Fault code : HCESPN 133, FMI 0~4
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
侍
1)
Wiring diagram
CN-52
14
MCU
CN-51
3
13
SUPPLY
SIG
RETURN
A
B
C
CD-35
ARM IN/OUT & BUCKET IN
PRESSURE SENSOR
300L6MS17
余
Cause
Remedy
Defective MCU
Detective arm in/
out & bucket in
pressure sensor
Short circuit or
poor connection
between CN-52
(14)-CD-35 (B)
Short circuit or
poor connection
between CD-35
(A)-CN-51(3) or
CD-35(C)- CN-51
(13)
Replace
Replace or repair
Replace or repair
Replace or repair
Check voltage
between CN-52
(14) - GND
YES
YES
NO
SPEC :
Key ON : 24
佳
2V
Starting switch ON
Check voltage
between CD-35
(A)-(C)
SPEC :
Actuator operating: 1~5V
See TEST 15
NO