3-5
The pilot circuit consists of suction circuit, delivery circuit and return circuit.
The pilot pump is provided with relief valve, receives the oil from the hydraulic tank through the
suction strainer.
The discharged oil from the pilot pump flows to the remote control valve through line filter, EPPR
valve, solenoid valve assemblies, swing parking brake, main control valve and safety lock solenoid
valve.
GROUP 3 PILOT CIRCUIT
Relief valve
40 kgf/cm
RCV pedal
Remote control valve
(LH lever)
Remote control valve
(RH lever)
Safety lock
solenoid valve
Swing parking brake
Pilot pump
Suction strainer
MCV
Travel speed solenoid valve
Main pump
2
Power boost solenoid valve
Line filter
Boom priority EPPR valve
430L3CI01