6-67
Wiring diagram
SPEC : 20~30V
Starting switch ON
Check resistance
between
CN-133(1)-(2)
Short circuit or poor
connection between
CN-52(35)-CN-133
(1) or CN-52(34)-
CN-133(2)
Defective EPPR
valve
Repair or replace
Repair or replace
15. MALFUNCTION OF BOOM PRIORITY EPPR VALVE
Fault code : HCESPN 141, FMI 5 or 6
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
侍
1)
CN-133
1
2
BOOM PRIORITY
EPPR VALVE
35
CN-52
34
MCU
Cause
Remedy
YES
NO
300L6MS23