Appendix B • Installing the DW6000 using the Installer Console
1033295-0001 Revision A
123
Powering up and
reading the DW6000
LED display
If the DW6000 for your installation uses an AC/DC power
supply, and the power supply’s AC power cord is connected to a
power strip or surge protector, connect the power strip or surge
protector to a 110 V wall outlet or other AC power source.
The DW6000 LEDs will come on in the following order:
1. Power LED comes on solid to indicate the DW6000 is
powered up.
2. LAN LED comes on within 30 seconds to indicate LAN
connectivity is detected.
3. Power LED blinks, indicating the unit is not commissioned
and therefore is running fallback.bin and not main.bin.
Obtaining the IP address
and testing the Ethernet
connection
1. Restart the installer PC so the DW6000 assigns it an IP
address. Or type the command
ipconfig /renew
at a DOS
command line prompt.
2. The embedded DHCP server assigns IP address 192.168.0.2
to the installer PC. The DW6000 Address is set to
192.168.0.1. Figure 111 shows a sample Windows TCP/IP
Properties screen.
3. Type
Ping 192.168.0.1
at the DOS prompt and press
E
NTER
. Figure 112 shows a successful ping attempt;
Figure 113 shows an unsuccessful attempt.
If the computer
fails to ping the DW6000
, check that you installed the NIC
properly and followed the instructions in Appendix C –
Configuring the installer laptop for IP addressing,
on
page 141.
If the NIC is installed properly and TCP/IP is configured
correctly, check that all the cable connections are secure. If
they are, unplug the DW6000 from the power source; shut
down and power off the computer; plug the DW6000 back in,
and turn the computer back on. Then try the ping test again. If
it is unsuccessful, call installer support for assistance.
Note:
In countries outside North America, the DW6000 may be
plugged, with a physical adapter, directly into a 220 V outlet.
Different countries may have different standards and requirements.
Note:
Whenever the LEDs do not function properly as described
in this section, make sure you have the correct power supply. Refer
to page 117 for more information on power supplies.
Note:
The appearance of the TCP/IP Properties screen may
vary among Windows operating systems.
Summary of Contents for Direcway DW6000
Page 1: ...1033295 0001 Revision A March 31 2006 Hughes DW6000 DW6002 Series Installation Guide ...
Page 8: ... Contents viii 1033295 0001 Revision A ...
Page 14: ... Figures xiv 1033295 0001 Revision A ...
Page 16: ... Tables xvi 1033295 0001 Revision A ...
Page 88: ...Chapter 3 The System Control Center 66 1033295 0001 Revision A ...
Page 104: ...Chapter 4 DW6000 LEDs and troubleshooting 82 1033295 0001 Revision A ...
Page 192: ...Appendix E Using the Fallback Updater utility 170 1033295 0001 Revision A ...
Page 196: ...Appendix F Disabling the Web browser s proxy connection 174 1033295 0001 Revision A ...
Page 198: ...Appendix G Installation checklist 176 1033295 0001 Revision A ...
Page 204: ...Appendix I Declaration of Conformity 182 1033295 0001 Revision A ...
Page 205: ...Appendix I Declaration of Conformity 1033295 0001 Revision A 183 ...
Page 206: ...Appendix I Declaration of Conformity 184 1033295 0001 Revision A ...
Page 210: ... Abbreviations and Acronyms 188 1033295 0001 Revision A ...