RUN indicator (green)
l
Blinks every 2 seconds (0.5 Hz): The SPU is running
normally.
l
Blinks four times every second (4 Hz): The SPU is in the
alarm state or starting but not registered.
SPC
! NOT SWAP
The SPC and SPU share one sales code in a slot. They both
must be replaced at the same time.
OFL button
To remove an SPC, press and hold the OFL button for six
seconds until the OFL indicator turns red for one second and
then turns off.
OFL indicator
l
If the indicator is green and blinks once every second (1
Hz), the SPC is running normally.
l
If the indicator is green and blinks four times every second
(4 Hz), the SPC is in the alarm state or starting but not
registered.
l
If the indicator turns red for one second and then turns off,
you can safely remove the SPC.
Interface Attributes
The SPUB-20-O-M does not have external interfaces.
Technical Specifications
lists the technical specifications of the SPUB-20-O-M.
Table 1-65
Technical specifications of the SPUB-20-O-M
Item
Specifications
Board silkscreen name
SPUE
SPUB-20-O-M
Dimensions (width x
depth x height)
400 mm x 520 mm x 41 mm
Typical power
consumption
280 W
Maximum power
consumption
300 W
Typical heat
consumption
955.4 BTU/hour