Figure A-7
OT bare crimping terminal
shows the JG2 double-hole bare crimping terminal without a cable.
Figure A-8
JG2 double-hole bare crimping terminal
NOTICE
If the power supply distance is longer than 35 m, you must place the DC power distribution
cabinet closer to the USG9500.
Prepare cables according to the distance between the USG9500and the power distribution
cabinet.
Power Supply Distance Shorter Than 3 m (Cables Between the AC power chassis
and the USG9560)
Place the AC power chassis as close to the device as possible. If the distance is shorter than or
equal to 3 m, use the cabling scheme described in
.
Table A-5
Cable types and terminals of the AC-input power cable
Item
Description
Cable Type NEG
power
cable (-48
V)
Wire,450/750V,60227 IEC 02(RV)16mm
2
,blue,85A
RTN
power
cable
Wire,450/750V,60227 IEC 02(RV)16mm
2
,black,85A
HUAWEI USG9500 Series
Hardware Guide
A Appendix
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
421