Slave
8 PWR Present Registered Normal
NA
9 PWR Present Registered Normal
NA
10 FAN Present Registered Normal NA
l
Run the
display device pic-status
command on the console interface to view the running
status of FPICs. If the FPICs on the corresponding LPUs are working normally, the
following is displayed:
<sysname>
display device pic-status
Pic-status information in Chassis
1:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
SLOT PIC Status Type Port_count Init_result Logic
down
Registered
Cpu
1 1 Registered SPU_CARD_TYPE_SPCC 0 SUCCESS
SUCCESS
CPU3
2 1 Registered ETH_12XGE_CARD 12 SUCCESS
SUCCESS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
Step 10
Check whether services are working normally.
----End
Follow-up Procedure
After replacing the FPIC, collect all tools. If the replaced FPIC is faulty, fill in the
and send the faulty module with the Repair Transmission Sheet to the
equipment supplier or the specified repair service provider.
3.1.5 Replacing an SPU
This section describes the precautions and procedures for replacing an SPU.
Context
The new SPU must be of the same type as the one that is to be replaced.
Tool
Before replacing the SPU, you need the following tools:
l
ESD wrist strap or ESD gloves
l
Phillips screwdriver
l
ESD bag
Procedure
Step 1
Check the location of the SPU to be replaced.
Before pulling out the SPU to be replaced, first check the location of the SPU, that is, the
cabinet and chassis where the SPU resides, and label it.
HUAWEI USG9500 Series
Hardware Guide
3 Hardware Maintenance
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
356