! NOT SWAP
Name
Description
SPU
OFL button
To remove an SPU, press and hold the OFL button for six
seconds until the OFL indicator turns on.
OFL indicator (red)
Steady on: You can remove the SPU.
RUN indicator (green)
l
Blinks every 2 seconds (0.5 Hz): The SPU is running
normally.
l
Blinks four times every second (4 Hz): The SPU is in the
alarm state or starting but not registered.
SPC
! NOT SWAP
The SPC and SPU share one sales code in a slot. They both
must be replaced at the same time.
OFL button
To remove an SPC, press and hold the OFL button for six
seconds until the OFL indicator turns red for one second and
then turns off.
OFL indicator
l
If the indicator is green and blinks once every second (1
Hz), the SPC is running normally.
l
If the indicator is green and blinks four times every second
(4 Hz), the SPC is in the alarm state or starting but not
registered.
l
If the indicator turns red for one second and then turns off,
you can safely remove the SPC.
Interface Attributes
The SPU-X3-20-O-E8KE does not have external interfaces.
Technical Specifications
lists the technical specifications of the SPU-X3-20-O-E8KE.