Follow-up Procedure
After you power on the USG9500, check the connection by looking at the optical port
indicator. If the indicator is on or blinking, the link is connected or data is being transmitted.
If the indicator is off, the link is disconnected. Possible disconnection causes include:
l
The optical fiber is improperly inserted. Pull out the optical fiber and re-insert it.
l
The Rx and Tx optical ports are reversed. Pull out the optical fibers and re-insert them
into the correct ports.
l
The optical module or optical fiber is damaged and must be replaced.
2.3.10 Checking After Installation
After you install the device in a cabinet and before you power on the device, verify that the
cables and NE40E have been installed correctly.
Cabinet Installation Checklist
No.
Item
1
The cabinet is positioned according to instructions in the
engineering design document.
2
The deviation of the cabinet is less than 3 mm horizontally and
not more than 3 mm vertically.
3
All bolts are firmly fastened, especially those for electrical
connections. Both flat washers and spring washers are used and
the spring washers are placed over the flat washers.
4
The cabinet is neat and clean.
5
The doors can be opened and closed smoothly.
6
All labels, tags, and nameplates are correct, legible, and
complete.
Installation Environment Checklist
No.
Item
1
The equipment is free of fingerprints or other smudging.
2
The cables are free of excessive electrical tape and cable ties.
3
The area around the equipment is free of tape, cable ties,
packaging bags, and trash.
4
All items around the equipment are neat, clean, and intact.