Figure 3-6
Inserting a new SFU
Step 6
Check the running status of the new SFU.
Normally, after the new SFU is inserted into the chassis, the SFU automatically communicates
with the boards in the chassis. In this case, you can check the running status of the new SFU
in the following ways:
l
Check the RUN indicator on the panel of the SFU. If it is on (green), the SFU is working
normally.
l
Check the alarms. If the system does not generate any alarm related to the new SFU, the
SFU is working normally.
l
Run the
display device
command on the console interface. If the SFUs are working
normally, the following is displayed:
<sysname>
display device
USG9560's Device status:
Slot # Type Online Register Status Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 SPU Present Registered Normal NA
2 SPU Present Registered Normal NA
3 SPU Present Registered Normal NA
4 SPU Present Registered Normal NA
5 SPU Present Registered Normal NA
6 LPU Present Registered Normal NA
7 LPU Present Registered Normal NA
8 LPU Present Registered Normal NA
9 MPU Present NA Normal Master
10 MPU Present Registered Normal Slave
11 SFU Present Registered Normal NA
12 SFU Present Registered Normal NA
13 SFU Present Registered Normal NA
14 CLK Present Registered Normal Master
15 CLK Present Registered Normal Slave