Step 4
Lay out the network cable along a cabinet and route the cable through the cable hole for the
signal cables at the top (overhead cabling) or bottom (underfloor cabling) of the cabinet.
Step 5
Remove the temporary labels and attach labels (20 mm away from the connectors) at each end
of the network cable.
----End
Follow-up Procedure
Verify the following:
l
The labels at each end of the cable are correct, clear, neat, and facing the same direction.
l
The cables and connectors are free of any damage and are connected properly and
securely.
2.4.9 Connecting Optical Fibers
This section describes how to install optical transceivers on the ports and connect them to the
ports of the peer device using optical fibers according to the network plan.
Installing Fiber Spools
NOTE
Wind excess optical fibers around fiber spools for convenient cable routing and device maintenance.
Determine the locations of the fiber spools based on the device arrangement in the cabinet. Positioning
the fiber spools too close to the device operation area may inhibit board insertion or removal or cabling.
However, positioning the fiber spools too far away from the device may inhibit fiber spool operation.
Figure 2-60
Installing fiber spools
M6
Install the fiber spool
(left)
Install the fiber spool
(right)
M6
HUAWEI USG9500 Series
Hardware Guide
2 Hardware Installation