background image

 

>>

Network 

Application Platforms

Hardware platforms for next generation networking infrastructure

FW-8877

V1.2

User's Manual

Publication date:  2015-02-23

Summary of Contents for FW-8877

Page 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 8877 V1 2 User s Manual Publication date 2015 02 23...

Page 2: ...er the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties that may result from such use Acknowledgement Intel Pentium and Celeron ar...

Page 3: ...ulation Be sure that the room in which you choose to operate your system has adequate air circulation Ensure that the chassis cover is secure The chassis design allows cooling air to circulate effecti...

Page 4: ...e ad quate pour refroidir l quipement une temp rature de fonctionnement acceptable sans circulation adapt e V rifiez que votre site propose une circulation d air ad quate V rifiez que le couvercle du...

Page 5: ...plication Platforms Revision History Version Changes 1 1 Add the IPMI board connector LOM1 de scription in the introduction part page 3 Add FastBoot option description in the BIOS 1 2 Modified rear PC...

Page 6: ...oard Layout 11 Jumper Settings 12 Chapter 4 BIOS Settings 16 Accessing the BIOS menu 16 Navigating the BIOS menu 16 The Main Menu 17 Advanced Settings 18 Chipset 27 Boot Configuration 28 Security Sett...

Page 7: ...600 series Chipset OS Support Windows 7 8 2000 Vista Server 2008 2012 Linux Kernel 2 6 or above BIOS AMI BIOS 64Mb System Memory Technology Quad channel DDR3 800 1066 1333 1600 MHz Registered ECC Ecc...

Page 8: ...ents Your package contains the following items FW 8877 Network Security Platform 1 passive CPU heatsink 2 power cables 1 crossover Ethernet cable 1 8 meters 1 straight through Ethernet cable 1 8 meter...

Page 9: ...onnected for configuration or troubleshooting purpose Conformity with IPMI Intelligent PlatformManagementInterface canbeimplementedthroughOPMAonthisinterface Youneedtoswitchtheconnectors on the mainbo...

Page 10: ...f the Intel Virtualization Technology to improve networking and I O throughput on a virtualized system Turn on the Virtualization support on the chipset refer to Chapter 4 BIOS Settings for more infor...

Page 11: ...Switch When the alarm sounds it indicates a power supply failure switch off this button to turn off the alarm Replace the failed power supply as soon as possible R5 Redundant Power Supply The 400W re...

Page 12: ...the higher bandwidth requirements of the latest operating system and Internet applications It comes with Quad Channel DDR3 Dual Inline Memory Modules DIMM sockets Open the DIMM slot latches 1 Install...

Page 13: ...the sequence as instructed on the right to release both of them Lift the load lever and then the plate 3 Align the cut edge of the CPU and the notch on the 4 socket The CPU should fit perfectly into...

Page 14: ...he hard disk with the mounting holes on the tray Secure the hard disk with 4 mounting screws on the 3 hard disk tray Connect the Serial ATA power and data cables to the 4 hard disk s power and data co...

Page 15: ...9 Hardware Setup Chapter 2 Network Application Platforms...

Page 16: ...6 1333 1600MHz ECC Non ECC DIMM Compact Flash SPIF 223A Com Ports LCM Key Pad GPIO Fan Monitor SPI 64Mb Flash 2x USB for front IO W83627DHG Thermal Monitor DMI Intel Patsburg J PCH LPC SATAII USB 2 0...

Page 17: ...picture as a reference of the pin assignments and the internal connectors OPMA1 USB2 DIMM Socket AJ1 AJ2 BJ1 BJ2 Reset Switch SW2 LOM1 Fan 2 DIMM Socket DJ2 DJ1 CJ2 CJ1 CPU Socket No 1 AT Mode Power...

Page 18: ...ATA4 SATA Revision II Drive Connector It is for connecting a 3 5 SATA harddisk to be served as your system s storage The system can support up to one 3 5 or two 2 5 disks in maximum The system s BIOS...

Page 19: ...ux kernel version 2 6 27 the mdadm utility 3 0 supports RAID 0 RAID 1 RAID 5 and RAID 10 To use the RAID features in dmraid and mdadm you will need to set up the RAID volume using the Intel Matrix Sto...

Page 20: ...face connector CF1 CF Card Connector Pin No Description Pin No Description 1 GND 26 CD1 2 DATA3 27 DATA11 3 DATA4 28 DATA12 4 DATA5 29 DATA13 5 DATA6 30 DATA14 6 DATA7 31 DATA15 7 CE1 32 CE2 8 A10 33...

Page 21: ...per to reset the BIOS setting to its factory default TTL1 Redundant power Supply TTL time to live signal It detects and reads the operating status of the power supply 3 2 1 and white latched slots is...

Page 22: ...or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to...

Page 23: ...blue can be modified The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often...

Page 24: ...scribed on the following pages Restore AC Power Loss This option lets you set the state of the system when it has just recovered from a power outage Option Description Power Off When setting to Power...

Page 25: ...em Use the Plus and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described below Item Selection Int...

Page 26: ...etch of next L1 line based on sequential load history Intel Virtual ization The Intel VT is a hardware assisted virtual ization This processor supports Intel Vir tualization Enable or disable this fea...

Page 27: ...nly available on SATA controllers that use the Advanced Host Controller Interface AHCI Serial ATA Port 0 1 2 3 4Use this menu to configure specific SATA Port for all ports on the system Option Descrip...

Page 28: ...SB compatible operating system is fully booted with all USB drivers loaded When this option is enabled any attached USB mouse or USB keyboard can be used on the system even when there is no USB driver...

Page 29: ...re Delays a The menu sets delay time for USB operations Item Description USB transfer time out set transfers to an endpoint to complete within a specific time If set to zero transfers will not time ou...

Page 30: ...or automatically detects the voltage output through the onboard voltage regulators Smart Fan Mode Configuration It allows you to configure the smart fan feature You can manually turn on the fans or en...

Page 31: ...ip Serial Port 0 1 Configuration This option specifies the base I O port address and Interrupt Request address of serial port 0 and 1 item Selection Enabled Disabled Set this value to prevent the seri...

Page 32: ...Redirection Enable or disable BIOS through remote access Console Redirection Set tings Enter to view more options COM0 COM1 Console Redirection Settings Item Selection Terminal Type Sets the connecti...

Page 33: ...ngs Chapter 4 Network Application Platforms Chipset The chipset menu will let you further configure your Intel PCH information It also shows the memory capacity of the system and the installed memory...

Page 34: ...figure the boot procedures and the related elements Items Options Setup Prompt Timeout Specify the number of seconds for the boot setup prompt to wait for user s intervention during the POST Bootup Nu...

Page 35: ...se you will only be able to see or change selected fields in the BIOS setup program User Password If you have set a user password you must enter the user password for booting the system and accessing...

Page 36: ...ers can take effect Discard Changes and Reset This option allows you to discard the selections you made and restore the previously saved values After selecting this option a confirmation appears Selec...

Page 37: ...e counter reach zero before the software restarts it the software is presumed to be malfunctioning and the processor s reset signal is asserted Thus the processor will be restarted as if a human opera...

Page 38: ...cable to console port 1 of the system and the other end to serial port of the Remote Client System Configure the following settings in the BIOS Setup 2 menu BIOS Advanced Remote Access Configuration...

Page 39: ...Note omit the file extensions After compiled the executable programs plcm_test plcm_cursor_char Test and the driver plcm_drv ko or plcm_drv o will appear in the program s folder Note The OS supported...

Page 40: ...allation on platforms 2 other than Linux see lanner serial usb lcm v0 5 README and lanner serial usb lcm v0 5 dos example README Install To install type the following command mknod dev usb hiddev0 c 1...

Page 41: ...pset driveronaWindowsOperating System Restart the computer and then log on with 1 Administrator privileges Insert the Drivers and User s Manual CD to the USB 2 optical drive Browse the contents of the...

Page 42: ...izard window appears Select the I accept the terms in the license agreement 6 and then click Next Select the programs that you wish to install Make sure 7 that you have selected the drivers Click Nest...

Page 43: ...er module by typing the following 5 command make install The binary will be installed as 6 lib modules kernel_version kernel drivers net e1000 o The install locations listed above are the default loca...

Page 44: ...er s Manual CD to the optical 1 drive Or you can download this software from Intel website too Browse the contents of the support CD under the 2 directory Driver for RAID software Follow the on screen...

Page 45: ...ll be returned at customer s expense The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineer...

Page 46: ...ing by Air Freight Sea Express ___ Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04...

Reviews: