Standards for Continuing the
Commissioning
3
Automati
cally
upgrade
the
software
The M2000 automatically checks
whether the target GBTS version
and the current GBTS version are
consistent according to the target
version information provided in the
deployment list.
l
If the versions are consistent, the
GBTS software need not be
upgraded.
l
If the versions are inconsistent,
the M2000 instructs the GBSC to
start upgrading the GBTS
software. The GBTS downloads
the target version from the
M2000 and upgrades the
software.
The parameters for upgrading
the GBTS software are as
follows:
–
Load mode: Load by
Configuration and Abis Quick
Load(No Service).
–
Automatically Load and
Activate Switch: Determined
by the
vercfg.xml
file in the
software package.
NOTE
The upgrade of the GBTS
configuration data is not controlled by
the M2000. After the GBTS software
is upgraded and the GBTS is reset, the
GBTS automatically sends a request to
the GBSC for loading configuration
data.
You can set the M2000 to skip the
software upgrade when starting the
commissioning task.
l
If the software need not be
upgraded or is already upgraded
successfully, the M2000
automatically proceeds with the
next procedure.
l
If the software fails to be
upgraded, the commissioning
automatically stops and switches
to the
Abnormal
status.
5 Commissioning the MBTS in GL or UL Mode on the