No
.
Procedu
re
Description
Standards for Continuing the
Commissioning
2
Automati
cally
detect the
OML
The M2000 automatically checks
the status of the OML between the
GBTS and the GBSC managing the
GBTS.
The M2000 automatically proceeds
with the next procedure only when
the OML between the GBTS and
the GBSC managing the GBTS is
normal. The details are as follows:
l
If the OML is normal and you
have not set intervention on the
commissioning task during the
task startup, the M2000
automatically proceeds with the
next procedure.
l
If the OML is normal and you
have set intervention on the
commissioning task during the
task startup, the commissioning
switches to the
Intervening
transmission
status and a
transmission loopback test is
required.
l
If the OML is abnormal after the
OML detection is performed
three times, the M2000
determines that the OML is
faulty. In this case, the
commissioning automatically
stops and switches to the
Abnormal
status.
3900 Series Multi-Mode Base Station
Commissioning Guide
5 Commissioning the MBTS in GL or UL Mode on the
M2000
Issue 02 (2010-07-30)
Huawei Proprietary and Confidential