Parameter
Description
OM VLAN ID
VLAN ID of the NodeB configured at the RNC (it must be exported
from the CME if the VLAN is planned)
This parameter can be optionally exported from the CME. It is not
configurable in the
NodeB Auto Deployment
window.
OM VLAN Priority
VLAN priority of the NodeB configured at the RNC (it must be
exported from the CME if the VLAN is planned)
This parameter can be optionally exported from the CME. It is not
configurable in the
NodeB Auto Deployment
window.
DHCP VLAN ID
Same value as OM VLAN ID (it must be exported from the CME if
the VLAN is planned)
This parameter can be optionally exported from the CME. It is not
configurable in the
NodeB Auto Deployment
window.
PING VLAN ID
Same value as OM VLAN ID (it must be exported from the CME if
the VLAN is planned)
This parameter can be optionally exported from the CME. It is not
configurable in the
NodeB Auto Deployment
window.
OM PING IP address OM ping IP address
This parameter must be exported from the CME. It is not configurable
in the
NodeB Auto Deployment
window.
OM PING IP Subnet
mask
OM ping subnet mask
This parameter must be exported from the CME. It is not configurable
in the
NodeB Auto Deployment
window.
NodeB Type
Type of the NodeB to be commissioned
This parameter must be exported from the CME. It is not configurable
in the
NodeB Auto Deployment
window.
NodeB BaseLine
Software Version
Baseline version of the target NodeB (it must be exported from the
CME if the target version is planned)
This parameter can be optionally exported from the CME. It is
configurable in the
NodeB Auto Deployment
window.
NodeB Cold Patch
Version
Version of the cold patch of the target NodeB (it must be exported
from the CME if the target version is planned)
This parameter can be optionally exported from the CME. It is
configurable in the
NodeB Auto Deployment
window.
NodeB Hot Patch
Version
Version of the hot patch of the target NodeB (it must be exported
from the CME if the target version is planned)
This parameter can be optionally exported from the CME. It is
configurable in the
NodeB Auto Deployment
window.
NodeB Configuration
File CRC
CRC value of the NodeB data configuration file
This parameter can be optionally exported from the CME. It is not
configurable in the
NodeB Auto Deployment
window.
3900 Series Multi-Mode Base Station
Commissioning Guide
5 Commissioning the MBTS in GL or UL Mode on the
M2000
Issue 02 (2010-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5-57