Details and solution
Description
Error code
•
Early firmware versions were not able to
use as much force to get or place media
in a magazine. Upgrading the Library
firmware might resolve this issue.
•
If the error consistently happens on the
same slot, try different tape cartridges in
that slot.
• If the failure remains with the same
slot, the magazine may be at fault.
• If the failure follows the tape cart-
ridge, the tape cartridge may be at
fault.
•
If the device is performing an operation
that automatically returns a tape cartridge
to a certain slot, make sure another tape
is not loaded in that slot.
•
Run the wellness test
Ends of slider
2
movement not in expected
range
8F
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Ends of elevator
3
movement not in expected
range
90
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Ends of rotation
4
movement not in expected
range
91
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Ends of sled
5
movement not in expected
range
92
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Gripper
1
reached a position beyond
expected range
93
Slider
2
reached a position beyond expected
range
94
Elevator
3
reached a position beyond
expected range
95
Rotation
4
reached a position beyond
expected range
96
Sled
5
reached a position beyond expected
range
97
•
Power cycle the device and retry the op-
eration.
Cartridge present sensor not found
98
Slider
2
home sensor not found
99
Rotation
4
home sensor not found
9A
Troubleshooting
188
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...