5.
Tighten the blue thumbscrews by hand to secure the power supply to the chassis as shown in
Figure 27 Redundant power supply thumbscrews
.
Changing the SCSI address (parallel SCSI drives only)
On a parallel SCSI device, if you need to change the SCSI ID for one or both of the tape drives, do
so before connecting the Library to the host computer.
The pre-configured SCSI address for all full-height tape drives in the MSL2024 and MSL4048, and
for all drives in the MSL8048 and MSL8096 is 4. For half-height drives in the MSL2024 and MSL4048,
the bottom drive of any pair has SCSI address 4 and the top drive has SCSI address 5. If these
pre-configured addresses will not be unique on a bus, you must change the SCSI ID of one or more
tape drives.
To change the SCSI ID:
1.
Plug the power cord into the power connector on the back panel and then plug the cord into the
power outlet.
2.
From the front panel, push the round power button to power on the device.
3.
From the front panel, set the new SCSI ID for any drives that must have a different SCSI ID. For
the MSL2024, see “
Changing the SCSI address — parallel SCSI devices (Configuration > Change
” on page 115. For the MSL4048, MSL8048, or MSL8096, see “
configuration (Configuration > Drives)
4.
Power off the device by depressing the power button on the front panel.
TIP:
The SCSI ID can also be changed from the RMI
Configure: Drive
screen once the RMI is configured.
See
Changing the drive configuration
Connecting the parallel SCSI cable (parallel SCSI devices only)
NOTE:
LTO-3 and LTO-4 tape drives are Ultra 320 SCSI LVD devices. Use only cables and terminators
specified for Ultra 320 or labeled as MultiMode. LTO-2 tape drives are Ultra 160 SCSI LVD/SE
devices; use only cables and terminators specified for Ultra 160 or Ultra 320, or labeled as MultiMode.
Installing the Tape Library
52
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...