Operation problems
Table 29 Power problems
Solution
Problem
1.
Check all power cord connections.
2.
Make sure the power button on the front panel has been pressed,
and the green
READY
LED is lit.
3.
Make sure the outlet has power. Try another working outlet.
4.
Replace the power cord.
Device does not power on.
1.
Make sure the power cord is connected.
2.
Make sure the power button on the front panel has been pressed,
and the green
READY
LED is lit.
3.
Power cycle the device.
4.
If the display is still blank but the device seems to be powered on,
try to get the device status or error information from the RMI.
No display messages appear.
1.
Check all power cord connections.
2.
Make sure the power button on the front panel has been pressed,
and the green
READY
LED on the front panel is lit.
3.
Make sure the outlet has power. Try another working outlet.
4.
Replace the power cord.
All power supply LEDs are off
(MSL4048, MSL8048, and
MSL8096).
The blue LED is lit when the power supply is plugged into a good outlet.
The green LED is lit when the power supply is producing good power.
1.
Replace the power supply.
Blue power supply LED is lit and
green power supply LED is off
(MSL4048, MSL8048, and
MSL8096).
The yellow LED is lit when the power supply fan is not rotating at an
acceptable speed.
1.
Check the power supply fan for obstructions.
2.
Replace the power supply.
Yellow power supply LED is lit
(MSL4048, MSL8048, and
MSL8096).
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
159
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...