NOTE:
For optimal performance, a parallel SCSI tape drive should be the only device on the bus.
To connect the parallel SCSI cable to the device:
1.
HP recommends that the host server be powered off before attaching new devices.
2.
Attach one end of the parallel SCSI cable (included in the accessory package) to one of the
connectors on the back panel of the tape drive (see
).
Figure 28 Attaching the parallel SCSI cable to the tape drive
.
3.
Attach the other end of the parallel SCSI cable to the connector on the parallel SCSI host bus
adapter or to the connector on the previous device on the parallel SCSI bus.
NOTE:
The host bus adapter should be Low Voltage Differential Signaling (LVDS). A Single-Ended
(SE) SCSI host bus adapter works, but severely degrades performance and limits cable
length. If any SE devices are on the same parallel SCSI bus, all of the devices on the parallel
SCSI bus slow to SE speed, which severely degrades performance. Never attach an LTO-3
or LTO-4 tape drive to an SE SCSI bus.
4.
Attach the terminator to the remaining parallel SCSI connector on the back panel of the tape
drive if the Library is the last or only device on the parallel SCSI bus. Otherwise, attach one end
of a parallel SCSI cable to the remaining port and the other end to the next device on the parallel
SCSI bus. Make sure the last device on the parallel SCSI bus is properly terminated.
Connecting the Fibre Channel cables (Fibre Channel devices
only)
To connect the Fibre Channel cables to the Library:
1.
Remove the FC port caps if necessary. Attach one end of the Fibre Channel cable to Port A on
the tape drive as shown in
.
Figure 29 Attaching the Fibre Channel cable
.
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
53
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...