Figure 84 Mailslot-capable magazine and slot, each marked with a white dot
.
The Library will eject the mailslot in the lower left magazine when instructed to open mailslots. After
the mailslot is closed, the Library will inventory the tapes in the mailslot, but not the rest of the tapes
in the magazine, which allows the Library to resume operations sooner.
On the MSL8096, the upper-right magazine can be configured as a 12–slot mailslot. All of the
right-side magazines are the same so it does not have a special marking. When instructed to open
both mailslots, the Library first ejects the lower-left mailslot and then unlocks the upper-right mailslot
a few seconds later. The Library does not
eject
the upper-right mailslot. The upper-right mailslot remains
unlocked until 30 seconds after the lower-left mailslot is replaced. After the upper-right mailslot is
replaced, the Library inventories all of the tapes in the magazine. The OCP displays a series of
informative messages so you can see what the Library is doing.
NOTE:
If you exchange the magazine in the lower-left position with one that has different mailslot capabilities,
the Library displays a warning that the mailslot type is incompatible with the configuration.
To access the mailslots:
1.
Highlight
Operations -> Open Mailslots
and press
OK
to select it.
Figure 85 Operations menu
.
2.
On the MSL8096, if both mailslots are enabled, select which mailslots to open. The menu will
cycle through
Bottom Left (3)
,
Both (15)
, or
Top Right (12)
.
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
137
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...