Details and solution
Description
Error code
•
If the device was moved or shipped with
tape cartridges in the magazines, verify
that none of the cartridges is loose, ob-
structing access to the tape drive.
•
Remove all magazines and check for any
kind of obstruction.
•
Run the wellness test.
Rotation
4
obstructed
8C
•
MSL8048 and MSL8096: If the robotic
has been replaced, update the Library
firmware to the latest version.
•
MSL2024 and MSL4048: If this error
occurs on the first power-on after unpack-
ing or moving the device, or after repla-
cing the chassis, ensure that the shipping
lock was removed from the top and
stored on the back panel (see “
•
If the device was moved or shipped with
tape cartridges in the magazines, verify
that the cartridges did not come out of
the magazines to obstruct the robotic.
•
Ensure that nothing is stacked on top of
the device because any weight on top of
the device can bow the top cover down
and interfere with the robotics.
•
Ensure that the device is either mounted
in a rack with its rack kit or in a tabletop
conversion cover. The device must be
supported under both of its side edges
or the bottom can bow and impede robot-
ic movement.
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Sled
5
obstructed
8D
•
Remove all magazines and look for any
obstructions to the robot.
•
Run the wellness test.
Ends of gripper
1
movement not in expected
range
8E
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
guide
187
Summary of Contents for StorageWorks MSL2024
Page 16: ...16 ...
Page 216: ...Troubleshooting 216 ...
Page 240: ...Upgrading and servicing the Tape Library 240 ...
Page 244: ...Support and other resources 244 ...
Page 251: ...HP StorageWorks MSL2024 MSL4048 MSL8048 and MSL8096 Tape Libraries User and service guide 251 ...
Page 260: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 260 ...
Page 262: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 262 ...
Page 264: ...Regulatory compliance and safety 264 ...
Page 266: ...Electrostatic discharge 266 ...