Diagnostics
79
Edge Switch 2/12 Service Manual
7
A minor error occurred that caused the Fabric Services database to be
re-initialized to an empty state. As a result, a disruptive fabric logout and login
occurred for all attached devices. The following list explains the error:
■
Event code 011 - The Login Server database failed cyclic redundancy check
(CRC) validation.
■
Event code 021 - The Name Server database failed CRC validation.
All attached devices resume operation after fabric login. Perform the procedure
described in
Collect Maintenance Data” on page 105
. Exit MAP.
8
A minor error occurred that caused the Management Server database to be
re-initialized to an empty state. As a result, a disruptive server logout and login
occurred for all attached devices. The following list explains the error:
■
Event code 051 - The Management Server database failed CRC validation.
■
Event code 052 - An internal operating error was detected by the Management
Server subsystem.
All attached devices resume operation after Management Server login. Perform
the procedure described in
Collect Maintenance Data” on page 105
9
As indicated by an event code 061, a minor error occurred that caused the Fabric
Controller database to fail CRC validation and be re-initialized to an empty state.
As a result, the switch briefly lost interswitch link capability.
All interswitch links resume operation after CTP reset. Perform the procedure
described in
Collect Maintenance Data” on page 105
. Exit MAP.
Build fabric protocol error.
Go to
step 16
.
No principal switch.
Go to
step 18
.
No response from attached switch (hello timeout).
Go to
step 19
.
Table 12: Port Segmentation Reasons and Actions (Continued)
Segmentation Reason
Action