Diagnostics
77
Edge Switch 2/12 Service Manual
2
Does the customer want to install the E_Port (or Full Fabric) feature key?
YES
NO
↓
The switch appears operational and the inability to configure E_Ports
and connect the switch to another fabric element is acceptable to the
customer. No action is required. Exit MAP.
Install the E_Port (or Full Fabric) feature key. Refer to the HP StorageWorks
Edge Switch 2/12 Installation Guide for more information. Exit MAP.
3
Was an event code 011, 021, 051, 052, 061, 062, 063, 070, 071, 072, 140, 142, or
150 observed at the EWS Event Log?
YES
NO
↓
Go to
step 5
.
4
lists event codes, brief explanations of the codes, and suggested actions
to isolate faults.
Table 11: MAP 600 Event Codes
Event
Code
Explanation
Action
011
Login Server database invalid.
Go to
step 7
.
021
Name Server database invalid.
Go to
step 7
.
051
Management Server database invalid.
Go to
step 8
.
052
Management Server internal error.
Go to
step 8
.
061
Fabric Controller database invalid.
Go to
step 9
.
062
Maximum interswitch hop count exceeded.
Go to
step 10
.
063
Remote switch has too many ISLs.
Go to
step 11
.
070
E_Port is segmented.
Go to
step 12
.
071
Switch is isolated.
Go to
step 12
.
072
E_Port connected to unsupported switch.
Go to
step 20
.