Diagnostics
35
Edge Switch 2/12 Service Manual
9
A switch-to-PC Ethernet link problem (Ethernet too busy or IP address typed
incorrectly) is indicated.
1. Wait approximately five minutes, then attempt to login to the switch again.
2. At the Netsite field (Netscape Navigator) or Address field (Internet
Explorer), type
xxx.xxx.xxx.xxx
is the IP address of the switch (obtained in
step 1
). A
username and password entry dialog box appears.
3. Type the user name and password obtained in
step 1
and click OK. If the
View panel does not display, wait another five minutes and perform this step
again.
Does the EWS interface appear operational with the View panel displayed?
YES
NO
↓
Perform fault isolation at the switch. Go to
step 19
.
10
At the View panel and Switch page, inspect the Status field at the top of the page.
Does the switch status indicate Operational?
NO
YES
↓
The switch appears operational. Exit MAP.
11
Inspect Fibre Channel port operational states.
1. At the View panel, click the Port Properties tab. The Port Properties page
displays with port 0 displayed (