Event Codes
152
Edge Switch 2/12 Service Manual
Fan Module Events (300 through 399)
Table 41: Event Code 300
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan (out of three) failed or is rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
power supply assembly associated with the failed fan.
Action:
Replace the switch.
Event Data:
The first byte of event data (byte
0
) specifies the failed fan number (
0
through
2
inclusive).
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
Table 42: Event Code 301
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans (out of three) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the
power supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the switch.
Event Data:
The first byte of event data (byte
0
) specifies the failed fan numbers (
0
through
2
inclusive).
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔