Diagnostics
34
Edge Switch 2/12 Service Manual
6
A
Page cannot be found
,
Unable to locate the server
,
HTTP
404 - file not found
, or other similar message appears. The message
indicates the PC cannot communicate with the switch because:
■
The switch-to-PC Ethernet link could not be established.
■
AC power distribution in the switch failed, or AC power was disconnected.
■
The switch control processor (CTP) card failed.
Continue to the next step.
7
Ensure the switch reporting the problem is connected to facility AC power.
Inspect the switch for indications of being powered on, such as:
■
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
■
Illuminated LEDs adjacent to Fibre Channel ports.
■
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
A power distribution problem is indicated. Go to “
” on page 43. Exit MAP.
8
At the front of the switch, inspect the amber ERR LED.
Is the LED illuminated?
NO
YES
↓
A FRU failure or link incident is indicated. Go to
step 18
to obtain
event codes that identify the problem. Exit MAP.