Diagnostics
75
Edge Switch 2/12 Service Manual
37
Install the Flexport Technology feature key. Refer to the HP StorageWorks Edge
Switch 2/12 Installation Guide for more information.
Did installation of the key solve the problem?
NO
YES
↓
The switch appears operational. Exit MAP.
38
A transmission speed conflict between the port configuration and the SFP optical
transceiver is indicated.
1. At the EWS interface View panel, select Configure at the left side of the
panel. The Configure panel opens with the Ports page displayed.
2. At the Speed column, click the arrow adjacent to the list box for the port and
select a port speed as follows:
— Select 1 Gb/sec if a one gigabit per second (Gbps) optical transceiver is
installed in the port.
— Select 2 Gb/sec if a two Gbps optical transceiver is installed in the port.
3. Click Activate to save the change. The message
Your changes to the
Port Configuration have been successfully activated
appears.
Did reconfiguring the port speed solve the problem?
NO
YES
↓
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
39
A switch port state indicates No Light because a Fibre Channel device is not
attached to the port, or a problem exists with the fiber-optic cable, attached
device, or SFP optical transceiver.
Is a Fibre Channel device connected to the port?
NO
YES
↓
Go to
step 42
.