9.
Reconfigure the node as described in
Step 4
.
The warm failover feature will now automatically restore the original configuration and licenses.
The procedure is complete; you may omit the final step.
10.
Restore the previously saved configuration. See
Restoring the Configuration Settings
.
Replacing a Secondary Node
CAUTION:
Each VLS12000 node weighs 17.9 kg (39.5 lb) full. At least two people are required to lift and move
each node.
To replace a secondary node:
1.
Remove the existing node from the rack:
a.
Power off the system. See
Powering Off the System
.
b.
From the back of the node, make a note of all cable connections then disconnect the cables.
c.
From the front of the node, loosen the captive thumbscrews until the thumbscrews are free
of the rack.
d.
Pull the node out from the rack until it stops.
e.
Squeeze the release brackets (see
Figure 68
), then pull the node free from the rails.
2.
Install the new node into the rack. See
Installing the VLS Node into a Rack
.
3.
Reconnect the cables to the new node exactly as they were connected to the previous node.
4.
Configure the node according to the instructions provided in
Configuring the Secondary Nodes
1 through 7
.
5.
Reboot the system. See
Rebooting the System
.
Ethernet Switches
To replace the 100 Mb Ethernet Switch 2510–24 or the 1 Gb Ethernet Switch 2810–24G:
1.
Power off the switch.
2.
Make a note of all cable connections to the switch then disconnect the cables.
3.
From the front of the switch, loosen the captive thumbscrews until the thumbscrews are free of
the rack.
4.
Remove the switch from the rack.
5.
Install the new switch into the rack. See
Installing the 100 Mb Ethernet Switch 2510-24 into a
Rack
or
Installing the 1 Gb Ethernet Switch 2810-24G into a Rack
.
NOTE:
If you are replacing a 2824 with a 2810-24G, you will need to install new rails. The
2810-24G cannot use the 2824 rails.
HP StorageWorks
211
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...