NOTE:
The password can also be changed from the VLS CLI. See
CLI Management commands
.
Managing High Availability
This section describes the methods to maintain high availability with your VLS.
Array Dual Pathing
The VLS12000 Gateway supports dual pathing to the Gateway arrays, which provides path balancing
and transparent path failover on the VLS. Having followed the setup recommendations in the HP
StorageWorks VLS12000 Gateway virtual tape libraries solutions guide and the installation instructions
in this guide, each node on the VLS is connected to two fabrics/zones which are each connected to
the Gateway arrays by two or more paths. This assures that the VLS can establish two paths per LUN,
each path on a separate fabric/zone.
Load Balancing
For load balancing, half of the data transfer (from a specific node through a fabric to the array) is
conducted over one path; half over a second fabric, hence another path. The paths are selected as
follows: Once configured, the device recognizes all paths to each node on the device. From all
potential preferred paths and all potential secondary paths (see
Step 3
on page 39), the array assigns
one preferred path and one secondary path.
NOTE:
During each reboot the device is re-analyzed and the preferred and secondary paths are reassigned.
To view the preferred path for each LUN in the
Storage LUN Details
:
1.
In Command View VLS, select the System tab.
2.
Select
Storage LUNs
in the navigation tree.
3.
Select the
View
button for either
All
LUNs or the LUNs in the desired
<Storage Pool #>
.
Summary information displays at the top of the list. Preferred and secondary paths are listed after
the summary information in the
Storage LUN Details Per Node
sections.
NOTE:
It may take several minutes to display this information if there are many LUNs.
LUN Path Failover
LUN path failover allows the VLS12000 to automatically reroute data traffic usually assigned to one
(preferred) path to another (secondary) path when the preferred path fails. Path status is shown in
Command View VLS under
Storage LUN Details
.
Management
144
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...