![HP StorageWorks 12000 User Manual Download Page 118](http://html.mh-extra.com/html/hp/storageworks-12000/storageworks-12000_user-manual_160044118.webp)
5.
Select
Fibre Channel
in the navigation tree.
The Fibre Channel Host Ports window opens (
Figure 30
).
Figure 30 Fibre Channel Host Ports window
.
6.
Enter a value for the Loop ID in the
Loop ID Preferred
box for each Fibre Channel host port to
use for prioritizing communication requests with the VLS.
If the Fibre Channel host port's topology is Fabric, the Loop ID value is ignored.
7.
Select the Fibre Channel host port's topology in the
Topology Preferred
box for each Fibre Channel
host port.
Auto
—Allows the VLS to determine the Fibre Channel port's topology
Loop
—Sets the topology type to an arbitrated loop
Fabric
—Sets the topology type to fabric
8.
Select a link speed in the
Link Speed Preferred
box for each Fibre Channel host port.
Auto
—Allows the VLS to determine the Fibre Channel port's link speed
1
—1 Gb per second
2
—2 Gb per second
4
—4 Gb per second
9.
When you are finished configuring the Fibre Channel ports, click
Apply Settings
.
10.
Restart the VLS device emulations to make the changes take effect. See
“
Restarting VLS Device Emulations
” on page 147.
Managing Oversubscription
Because the VLS dynamically allocates storage space as data is written to virtual media, the VLS
allows you to allocate more cartridge capacity than is physically installed. This feature, called
oversubscription, permits configuring your system for anticipated storage growth; configure cartridges
beyond your current capacity and then seamlessly add physical storage later.
By default, oversubscription is disabled.
Configuration
118
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...