Current Status
The
Current Status
tab displays the overall performance and storage capacity information of the VLS
in gauges at the top of the page.
You can also select specific devices to display either the performance or the storage capacity used.
Show the performance of:
•
All Nodes
•
Pre-definied Views
Select one of the views from the list. You can create these views on the
Configuration
tab.
•
Most Active
(node, library, and tape drive)
Show the storage capacity (total and used) of:
•
All Storage Pools
•
All Virtual Libraries
•
Virtual Libraries per Storage Pool
(displays a pie chart instead of a gauge)
•
Storage Pools per Virtual Library
(displays a pie chart instead of a gauge)
Performance History
The
Performance History
tab displays a table of performance data for the selected nodes or devices
as designated in the
Configuration
tab.
To determine which devices display, select one of the following:
•
Nodes
•
Pre-define Views
, and then select a view from the list
Determine the duration of the data reported in the graphs. Valid entries are whole numbers between
one and 15.
NOTE:
The longer the duration you select, or the more nodes or devices your system has, the longer it may
take to generate a report.
To export the CSV data, enter the number of days to include in the report and click
Export
. (See
“
Exporting CSV Data
” on page 159 for more information on exporting CSV data.) See
Figure 52
for
an explanation of each field in a line of CSV data.
Figure 52 CSV data fields for VLS performance reports
.
HP StorageWorks
161
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...