2 Hardware Installation
This section details the steps to install the VLS hardware from installation preparation to final cabling.
Preparing for the Installation
Prepare the EVA for the VLS12000 Gateway
Arrays that will be connected to the VLS Gateway must already be setup with the appropriate
configuration as described in the solutions guide, including:
•
Command View EVA is installed, at firmware revision 5100 or later, and functioning properly.
•
There are either two external Fibre Channel switches/fabrics or two zones on an external Fibre
Channel switch/fabric so that there are two (high availability) data pathways from the VLS Gateway
to the EVA.
•
All of the VRaid LUNs required for the VLS have been created on the EVA according to the design
guidelines (for example, each LUN is roughly the same size—2 TB is preferred. The LUNs can not
be read-only. RAID 5 is recommended. Path failover is balanced across both EVA controllers).
NOTE:
Minimum capacity for EVA LUNs is 100 GB. Ensure all EVA LUNs attached to the Gateway meet
this requirement.
If this has not been done, refer to the solutions guide for instructions.
Tools for Installation
•
Two people
•
#1 and #2 Phillips screwdriver
•
Box cutting knife
CAUTION:
Do not use any power tools. They could strip or damage connections.
Taking ESD Precautions
To prevent damaging the system, be aware of the precautions you need to follow when setting up
the system or handling parts. A discharge of static electricity from a finger or other conductor may
damage system boards or other static-sensitive devices. This type of damage may reduce the life
expectancy of the device.
HP StorageWorks
17
Summary of Contents for StorageWorks 12000
Page 14: ...14 ...
Page 102: ...Operation 102 ...
Page 110: ...User Interfaces 110 ...
Page 150: ...Management 150 ...
Page 168: ...Monitoring 168 ...
Page 198: ...Component Identification 198 ...
Page 222: ...Support and Other Resources 222 ...
Page 232: ...Troubleshooting 232 ...
Page 236: ...Specifications 236 ...
Page 244: ...Bulgarian Notice Czech Notice Danish Notice Dutch Notice Regulatory Compliance Notices 244 ...
Page 245: ...Estonian Notice Finnish Notice French Notice German Notice HP StorageWorks 245 ...
Page 246: ...Greek Notice Hungarian Notice Italian Notice Latvian Notice Regulatory Compliance Notices 246 ...
Page 247: ...Lithuanian Notice Polish Notice Portuguese Notice Romanian Notice HP StorageWorks 247 ...
Page 249: ...Battery Replacement Notices Dutch Battery Notice HP StorageWorks 249 ...
Page 250: ...French Battery Notice German Battery Notice Regulatory Compliance Notices 250 ...
Page 251: ...Italian Battery Notice Japanese Battery Notice HP StorageWorks 251 ...
Page 252: ...Spanish Battery Notice Regulatory Compliance Notices 252 ...