Check the EBS matrix at http://www.hp.com/go/ebs to verify that your HBA is supported on your
server and qualified for the Autoloader.
A server that uses Fibre Channel disks needs at least two FC ports. Using the same port for disk and
tape access will cause performance degradation.
SAN connection
All switches between the host and the Autoloader must be of the appropriate type. A 2 Gb switch in
the path may result in performance degradation when backing up highly compressible data.
Configure zoning on the Fibre switch so only the backup servers may access the Autoloader. See the
switch manual for information on zoning.
Choosing a location
If you plan to mount the device in a rack, select an open rack location, ideally near the center of the
rack or higher, with access to the host server and a power outlet. You may also set the Autoloader
on a shelf in the rack. In this case you must attach the feet during the installation process.
If you plan to set the Autoloader on a table, select a level area large enough to support both edges
of the Autoloader with access to the host server and a power outlet.
Choose a location that meets the criteria shown in
Table 10
on page 31:
Table 10 Location criteria
Definition
Criteria
The Autoloader can only be placed on a flat surface if the support feet have been
properly applied or the Autoloader is mounted in the optional tabletop conversion
cover. Select a location that is flat, sturdy, and close to the host server. Ensure that all
of the feet on the Autoloader or tabletop conversion cover will be supported.
Do not place the device on the floor or other carpeted surface.
Do not place the Autoloader on its sides or upside down. Do not put anything on top
of the Autoloader unless the optional tabletop conversion cover is installed. The tabletop
conversion cover can support up to 15 kg (33 lb).
Tabletop
requirements
HP Rack 5000, 10000 Series, HP Rack System/E
Rack requirements
1U when mounted in the optional rack rails
Rack space
requirements
10-35º C (50-95º F)
Room temperature
AC power voltage: 100-127 VAC; 200-240 VAC
Line frequency: 50-60 Hz
Place the device near an AC outlet. The AC power cord is the product's main AC
disconnect device and must be easily accessible at all times.
Power source
11.5 kg (25.4 lb)
Weight without
media
13.1 kg (28.9 lb)
Weight with media
HP StorageWorks 1/8 G2 Tape Autoloader User and service guide
31
Summary of Contents for StorageWorks 1/8
Page 14: ...14 ...
Page 26: ...Features and overview 26 ...
Page 106: ...Operating the Tape Autoloader 106 ...
Page 156: ...Troubleshooting 156 ...
Page 168: ...Upgrading and servicing the Tape Autoloader 168 ...
Page 172: ...Support and other resources 172 ...
Page 174: ...Technical specifications 174 ...
Page 179: ...HP StorageWorks 1 8 G2 Tape Autoloader User and service guide 179 ...
Page 188: ...Battery replacement notices Dutch battery notice Regulatory compliance and safety 188 ...
Page 190: ...Italian battery notice Japanese battery notice Regulatory compliance and safety 190 ...
Page 192: ...Regulatory compliance and safety 192 ...
Page 194: ...Electrostatic discharge 194 ...
Page 204: ...204 ...