RBSU menu (HP ProLiant G7 servers or server blades) 16
For more information on Advanced Memory Protection, see the HP website
(
http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html
).
HP ProLiant DL580 G7 and HP ProLiant DL980 G7 Servers
The Advanced Memory Protection provides the following additional memory protection beyond ECC
(error checking and correcting):
•
Advanced ECC Support provides the largest memory capacity to the OS.
•
Online Spare with Advanced ECC Support enables the system to automatically map out a group of
memory that is receiving excessive correctable memory errors. This memory is replaced by a spare
group of memory.
•
Mirrored Memory with Advanced ECC Support provides maximum protection against uncorrectable
memory errors that would otherwise result in system failure.