RBSU menu (HP ProLiant G6 and earlier servers or server blades) 109
For more information on Advanced Memory Protection, see HP ProLiant Advanced Technology on the HP
website (
http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html
).
•
The Advanced ECC Support (maximum memory) setting disables additional resiliency and provides
the largest memory capacity to the OS.
•
The Online Spare with Advanced ECC Support setting requires a single group of spare modules and
provides automatic failover of degraded modules in the system while it is running.
•
The Mirrored Memory with Advanced ECC Support option provides protection against uncorrectable
memory errors that would otherwise result in system failure. DIMM banks A and B are mirrored by
DIMM banks C and D on the same memory board. The failed memory can be replaced while the
system is running.
Mirrored DIMM pairs must be the same size to allow selection of single-board mirrored memory or
dual-board mirrored memory. Pairing different size DIMMs results in the following caution:
Current memory configuration does not support Online Spare.
USB Control
The USB Control menu determines how USB ports and embedded devices operate at startup:
•
When USB Enabled is selected, all USB ports and embedded devices are enabled.
•
When USB Disabled is selected, all USB ports and embedded devices are disabled.
•
When Legacy USB Disabled is selected, all USB ports are enabled under a USB-aware OS, but USB
is not supported during POST or RBSU. Legacy USB Disabled also disables iLO 2 virtual devices.
Summary of Contents for ProLiant DL380e
Page 1: ...HP ROM Based Setup Utility User Guide Part Number 347563 402 September 2010 Eleventh Edition ...
Page 22: ...RBSU menu HP ProLiant G7 servers or server blades 22 The default setting is Enabled ...
Page 26: ...RBSU menu HP ProLiant G7 servers or server blades 26 The default setting is Enabled ...
Page 37: ...RBSU menu HP ProLiant G7 servers or server blades 37 Disabled ...
Page 44: ...RBSU menu HP ProLiant G7 servers or server blades 44 Disabled ...
Page 52: ...RBSU menu HP ProLiant G7 servers or server blades 52 5 minutes ...
Page 90: ...RBSU menu HP ProLiant G7 servers or server blades 90 Disabled ...
Page 95: ...RBSU menu HP ProLiant G7 servers or server blades 95 Disabled ...