Command Line Interface 140
Command Line Interface
Command Line Interface Overview
Both a full-screen, menu-driven user interface and a CLI are required to support both a Windows®/PC
background and a terminal/VT100 background. Full-screen, menu-driven utilities do not display correctly
on a VT100 interface because menus that get paged in and out require the entire screen to be redrawn.
CLI is being added to select newer servers because it provides a faster, more compatible solution for
VT100-compatible serial connections to servers using the BIOS Serial Console support.
Two basic commands, SET and SHOW, provide the foundation of the command tree wherever possible.
In addition, HELP can be accessed for commands, and EXIT or QUIT is used to exit the utility.
Dual-Mode ROM-Based Utilities
ROM-based utilities generically switch to run in either Windows® or VT100 mode to provide maximum
user benefit. RBSU also provides a user-configurable method for viewing and setting the console mode,
which is set before launching an Embedded ROM Utility remotely, through either a serial port connection
or iLO. The mode can also be set automatically.
CLI Mode Selection
On select newer servers, the BIOS automatically determines whether to run in CLI mode or full-screen,
menu-based mode for ROM embedded utilities. If a VT100-compatible terminal is being used with BIOS
Serial Console, CLI mode is selected for that boot. If BIOS Serial Console is disabled or not in use, the full-
screen, menu-based interface is used. You can force the utilities to always run in CLI mode by selecting
Command-Line Enable in the BIOS Interface Mode selection.
CQHCLI EV Value
Description
0 = Command-Line Disable
Disable CLI mode
1 = Command-Line Enable
Always enable CLI mode
2 = Auto CLI Enable
Auto determine CLI mode
Summary of Contents for ProLiant DL380e
Page 1: ...HP ROM Based Setup Utility User Guide Part Number 347563 402 September 2010 Eleventh Edition ...
Page 22: ...RBSU menu HP ProLiant G7 servers or server blades 22 The default setting is Enabled ...
Page 26: ...RBSU menu HP ProLiant G7 servers or server blades 26 The default setting is Enabled ...
Page 37: ...RBSU menu HP ProLiant G7 servers or server blades 37 Disabled ...
Page 44: ...RBSU menu HP ProLiant G7 servers or server blades 44 Disabled ...
Page 52: ...RBSU menu HP ProLiant G7 servers or server blades 52 5 minutes ...
Page 90: ...RBSU menu HP ProLiant G7 servers or server blades 90 Disabled ...
Page 95: ...RBSU menu HP ProLiant G7 servers or server blades 95 Disabled ...