117
Chapter 6, Call Processing Subsystem
Description of the Call Processing Subsystem
Accessing the Call Processing Subsystem’s Screens
The Call Processing Subsystem screens are accessed by selecting
CALL CNTL
from the
To Screen
menu on the Test Set’s CRT (you may have to choose the
More
choice to display the
CALL CNTL
choice).
Option 004:Tone/Digital Signalling is required in an HP 8920A in order to use the Call
Processing Subsystem. Attempting to access the Call Processing Subsystem without
Option 004 installed will generate an “Option not installed.” error.
Call Processing Subsystem’s Screens
The Call Processing Subsystem consists of six screens.
five
•
The CALL CONTROL is the primary Call Processing Subsystem screen. This screen
contains the fields used to configure the Test Set’s parameters such as SAT Tone fre-
quency, control channel number, and system identification number. Call processing
functions such as registration, page, and handoff can be activated from this screen. The
transmit power of the mobile station can be set from this screen. Data messages re-
ceived from the mobile station are displayed on this screen.
•
The CALL DATA screen displays the decoded signaling messages received from the
mobile station on the reverse control channel and the reverse voice channel. Call pro-
cessing functions such as registration, page, and handoff can also be activated from this
screen. The transmit power of the mobile station can be set from this screen.
•
The CALL BIT screen allows the advanced user to modify the contents of the forward
control channel and forward voice channel messages.
•
The CALL CONFIGURE screen contains the fields used to configure various parame-
ters related to the Call Processing Subsystem, such as
CMAX
,
Detector
, and
Input
Att
.
The ANALOG MEAS screen is used to make analog RF and audio measurements on the
mobile station while a link is active.
AUTHENTICATION screen allows the user to turn on the AMPS authentication process
(IS-54) during call processing functions. Various fields contained on this screen allow the
advanced user to select new
RAND_A
,
RAND_B
,
RandSSD
and
RAND_U
values for trans-
mission to the mobile station. The user can also select the number of times the system
parameter overhead message is sent to the mobile station.
AMPS
Call Processing functions
can be tested with or without authentication active.
Call Processing functions with Authentication are only supported for AMPS system types
(IS-54).
Summary of Contents for 8920A
Page 14: ...Contents 14 2 Configuring Your Test Set General Operating Information 50 ...
Page 17: ...Contents 17 5 AF Analyzer Screen Block Diagram 100 ...
Page 19: ...Contents 19 7 Configure Screen Field Descriptions 254 ...
Page 21: ...Contents 21 9 Duplex Test Screen Block Diagram 340 Field Descriptions 341 ...
Page 23: ...Contents 23 11 Help Screen Field Descriptions 436 ...
Page 24: ...Contents 24 12 I O Configure Screen Field Descriptions 438 ...
Page 25: ...Contents 25 13 Message Screen Field Descriptions 444 ...
Page 26: ...Contents 26 14 Oscilloscope Screen Field Descriptions 446 Using the Oscilloscope 452 ...
Page 27: ...Contents 27 15 Print Configure Screen Field Descriptions 454 ...
Page 29: ...Contents 29 17 RF Analyzer Screen Block Diagram 472 Field Descriptions 473 ...
Page 30: ...Contents 30 18 RF Generator Screen Block Diagram 484 Field Descriptions 485 ...
Page 31: ...Contents 31 19 RX Test Screen Block Diagram 494 Field Descriptions 495 ...
Page 32: ...Contents 32 20 Service Screen Field Descriptions 502 ...
Page 35: ...Contents 35 23 TX Test Screen Block Diagram 550 Field Descriptions 551 ...
Page 38: ...Contents 38 Index 619 ...
Page 39: ...39 1 Get Started ...
Page 99: ...99 5 AF Analyzer Screen ...
Page 113: ...113 6 Call Processing Subsystem ...
Page 268: ...268 S HP892XX USRGUIDE manual confscrn fb Chapter 7 Configure Screen Field Descriptions ...
Page 269: ...269 8 Signaling Decoder Screen ...
Page 339: ...339 9 Duplex Test Screen ...
Page 353: ...353 10 Signaling Encoder AF Generator 2 ...
Page 435: ...435 11 Help Screen ...
Page 437: ...437 12 I O Configure Screen ...
Page 443: ...443 13 Message Screen ...
Page 445: ...445 14 Oscilloscope Screen ...
Page 471: ...471 17 RF Analyzer Screen ...
Page 482: ...482 S HP892XX USRGUIDE manual rfanscrn fb Chapter 17 RF Analyzer Screen Field Descriptions ...
Page 483: ...483 18 RF Generator Screen ...
Page 492: ...492 S HP892XX USRGUIDE manual rfgscrn fb Chapter 18 RF Generator Screen Field Descriptions ...
Page 493: ...493 19 RX Test Screen ...
Page 504: ...504 S HP892XX USRGUIDE manual servscrn fb Chapter 20 Service Screen Field Descriptions ...
Page 519: ...519 22 Tests Screen ...
Page 548: ...548 S HP892XX USRGUIDE manual testscrn fb Chapter 22 Tests Screen ROM Programs ...
Page 549: ...549 23 TX Test Screen ...
Page 561: ...561 24 Connector Key and Knob Descriptions ...
Page 585: ...585 25 Modifications Accessories Manuals Support ...
Page 605: ...605 Error Messages ...
Page 618: ...618 S HP892XX USRGUIDE manual errormsg fb Error Messages ...