243
Chapter 6, Call Processing Subsystem
Using the CALL BIT Screen
Typical Example
The following example illustrates the use of the CALL BIT screen. In this
example an AMPS mobile station is brought up on a voice channel and then
handed off to a new voice channel assignment. The contents of the
FVC V Msg
message, which was set when the first handoff occurred, is then modified from the
CALL BIT screen. The mobile station is then handed off again by sending the
modified message to the mobile station from the CALL BIT screen.
1. Ensure that the Test Set is in the connected state.
See "Page a Mobile Station" on
for information on how to bring a mobile station up on a voice channel.
2. If the CALL CONTROL screen is not displayed, select
CALL CNTL
under the
To
Screen
menu. The CALL CONTROL screen will be displayed.
3. Position the cursor on the
Display
field and select
Data
.
4. Select the
Chan:
field and enter a new, valid voice channel number.
5. Select the
Pwr Lvl:
field enter a new, valid mobile station power level.
6. Select the
SAT:
field and enter a new, valid SAT frequency.
7. Select the
Handoff
field. The
Access
annunciator will light while the Test Set
signals the mobile station with the handoff information. If the mobile responds
properly, it will stop transmitting on the current voice channel, switch to the new voice
channel assignment, and transpond the new SAT frequency assignment. When the Test
Set detects that this has happened the
Connect
annunciator is lit indicating that the
handoff was successful. The left-hand fields in the
Voice Channel Assignment
section will be updated with the new voice channel assignment information.
8. Select
CALL BIT
from the
To Screen
menu. The CALL BIT screen will be
displayed.
9. Position the cursor on the
Data Spec
field and select
Bits
.
10. Select the
Set Message
field and select
FVC V Msg
.
11. Select the
VMAC
field in the
FVC V Msg
and set it to 101 (this corresponds to a mobile
station power level of 5 - reference EIA/TIA-553 Mobile Station - Land Station
Compatibility Specification, September 1989, page 2-2, Table 2.1.2-1).
12. Select the
Handoff
field. The
Access
annunciator will light while the Test Set
signals the mobile station with the handoff information. If the mobile responds
properly, it will stop transmitting on the current voice channel, and start transmitting on
the same channel with a power level of 5 (note that the channel assignment and SAT
assignment were not modified in this example, the mobile station simply switched to
the same channel with the same SAT assignment). When the Test Set detects that this
has happened, the
Connect
annunciator is lit indicating that the handoff was
successful. The mobile station power level after the handoff should be power level 5.
13. Position the cursor on the
Data Spec
field and select
Std
.
Summary of Contents for 8920A
Page 14: ...Contents 14 2 Configuring Your Test Set General Operating Information 50 ...
Page 17: ...Contents 17 5 AF Analyzer Screen Block Diagram 100 ...
Page 19: ...Contents 19 7 Configure Screen Field Descriptions 254 ...
Page 21: ...Contents 21 9 Duplex Test Screen Block Diagram 340 Field Descriptions 341 ...
Page 23: ...Contents 23 11 Help Screen Field Descriptions 436 ...
Page 24: ...Contents 24 12 I O Configure Screen Field Descriptions 438 ...
Page 25: ...Contents 25 13 Message Screen Field Descriptions 444 ...
Page 26: ...Contents 26 14 Oscilloscope Screen Field Descriptions 446 Using the Oscilloscope 452 ...
Page 27: ...Contents 27 15 Print Configure Screen Field Descriptions 454 ...
Page 29: ...Contents 29 17 RF Analyzer Screen Block Diagram 472 Field Descriptions 473 ...
Page 30: ...Contents 30 18 RF Generator Screen Block Diagram 484 Field Descriptions 485 ...
Page 31: ...Contents 31 19 RX Test Screen Block Diagram 494 Field Descriptions 495 ...
Page 32: ...Contents 32 20 Service Screen Field Descriptions 502 ...
Page 35: ...Contents 35 23 TX Test Screen Block Diagram 550 Field Descriptions 551 ...
Page 38: ...Contents 38 Index 619 ...
Page 39: ...39 1 Get Started ...
Page 99: ...99 5 AF Analyzer Screen ...
Page 113: ...113 6 Call Processing Subsystem ...
Page 268: ...268 S HP892XX USRGUIDE manual confscrn fb Chapter 7 Configure Screen Field Descriptions ...
Page 269: ...269 8 Signaling Decoder Screen ...
Page 339: ...339 9 Duplex Test Screen ...
Page 353: ...353 10 Signaling Encoder AF Generator 2 ...
Page 435: ...435 11 Help Screen ...
Page 437: ...437 12 I O Configure Screen ...
Page 443: ...443 13 Message Screen ...
Page 445: ...445 14 Oscilloscope Screen ...
Page 471: ...471 17 RF Analyzer Screen ...
Page 482: ...482 S HP892XX USRGUIDE manual rfanscrn fb Chapter 17 RF Analyzer Screen Field Descriptions ...
Page 483: ...483 18 RF Generator Screen ...
Page 492: ...492 S HP892XX USRGUIDE manual rfgscrn fb Chapter 18 RF Generator Screen Field Descriptions ...
Page 493: ...493 19 RX Test Screen ...
Page 504: ...504 S HP892XX USRGUIDE manual servscrn fb Chapter 20 Service Screen Field Descriptions ...
Page 519: ...519 22 Tests Screen ...
Page 548: ...548 S HP892XX USRGUIDE manual testscrn fb Chapter 22 Tests Screen ROM Programs ...
Page 549: ...549 23 TX Test Screen ...
Page 561: ...561 24 Connector Key and Knob Descriptions ...
Page 585: ...585 25 Modifications Accessories Manuals Support ...
Page 605: ...605 Error Messages ...
Page 618: ...618 S HP892XX USRGUIDE manual errormsg fb Error Messages ...