2-6
Operation
The Main Window
Wavelength Selection area
The Wavelength Selection area shows
the current wavelength settings. Single-
band systems only show the settings for
the single band. With dual-band systems,
only the settings for the selected band
are active. For example, this figure
shows the 1500 nm band active. To acti-
vate a band,
and turn on the appropriate
band.
Start and Stop
The start and stop wavelength settings define the limits of the test. The tun-
able laser source’s display shows an error message if the values in the start and
stop wavelength fields are greater than the range of the tunable laser source.
The HP 86037B application does not indicate an error. The shaded area in
shows the wavelength range where the selected tunable laser source
power is more than the tunable laser source can deliver. If you select a wave-
length range within the shaded area, the tunable laser source displays an error
and continue to put out as much power as it can.
Figure 2-2. TLS power roll-off in relation to wavelength range
# Steps and Delta
The
# Steps
field sets the number of measurement points between the start and
stop wavelengths. The
Delta
field shows the step size in nanometers between
each measurement point. After entering values for one of these fields, the sys-
tem automatically calculates the other field. The greater the number of data
P
o
w
e
r Le
ve
l
Wavelength Range
User-Selected
Wavelength Range
User-Selected
TLS Power
TLS power will be less than
user-selected power
TLS Output Power vs. Wavelength Curve
TLS Output Power vs. Wavelength Curve
TLS Output Power vs. Wavelength Curve
TLS Output Power vs. Wavelength Curve
Summary of Contents for 86037B
Page 1: ...User s Guide HP 86037B Chromatic Dispersion Test System ...
Page 31: ...2 13 Operation The Main Window Figure 2 4 Repeat Measurement Selector ...
Page 72: ...3 16 Normalization Setting Normalization Preferences ...
Page 94: ...4 22 Remote Control TES Parameters Main chromatic dispersion screen ...
Page 100: ...4 28 Remote Control TES Parameters CD and Gain Measurement Settings Dialog Box ...
Page 102: ...4 30 Remote Control TES Parameters Length Measurement Settings Dialog Box ...
Page 104: ...4 32 Remote Control TES Parameters Normalization Settings Dialog Box ...
Page 106: ...4 34 Remote Control TES Parameters New Normalization Button Dialog Box ...
Page 120: ...4 48 Remote Control Output Parameters ...
Page 158: ...5 38 Maintenance Hewlett Packard Sales and Service Offices ...
Page 170: ...6 12 Installation Installation ...
Page 174: ...7 4 Reference Theory of Operation Figure 7 3 HP 86037B Block Diagram Options 121 and 122 ...
Page 175: ...7 5 Reference Theory of Operation Figure 7 4 The HP 86037B Option 114 block diagram ...
Page 190: ...7 20 Reference System Options ...
Page 191: ...8 Specifications 8 3 Regulatory Information 8 7 Specifications and Regulatory Information ...
Page 204: ...Index 6 Index ...