2-16
Operation
The Main Window
TLS Target Power
Use this setting to specify the power level of the tunable laser source. Avoid
entering power levels beyond the capability of the tunable laser source.
Sensitivity
You can select from
Normal
,
High,
and
Highest
settings. Increasing sensitivity
reduces noise but increases the measurement time. The sensitivity setting
configures the IF bandwidth used by the network analyzer. Normal, high, and
highest correspond to 300, 100 and 30 Hz, respectively.
A measurement consisting of twenty wavelength steps might exhibit the mea-
surement times shown in the following table.
Average Factor
Increasing the average factor reduces noise when measuring group delay.
Because this factor controls the number of network analyzer sweeps which
are averaged to at each wavelength point, measurement time increases in pro-
portion to averaging factor. Noise is reduced by the reciprocal of the square
root of the averaging factor.
CD measurement only or CD and Gain measurement
Click these options to include gain measurements during your testing. For
measurements on fibers, the chromatic dispersion measurement is typically
the only measurement of interest. For measurements on filters or systems
containing optical amplifiers you may be interested in the passband of the
device under test because the chromatic dispersion data is meaningful only
within the passband. Selecting the
CD and Gain measurement
option increases the
measurement time.
Table 2-2. Example Measurement Times for 20 Measurement Steps
Sensitivity
Measurement Time
Normal
2 minutes, 50 seconds
High
4 minutes, 30 seconds
Highest
10 minutes, 5 seconds
Summary of Contents for 86037B
Page 1: ...User s Guide HP 86037B Chromatic Dispersion Test System ...
Page 31: ...2 13 Operation The Main Window Figure 2 4 Repeat Measurement Selector ...
Page 72: ...3 16 Normalization Setting Normalization Preferences ...
Page 94: ...4 22 Remote Control TES Parameters Main chromatic dispersion screen ...
Page 100: ...4 28 Remote Control TES Parameters CD and Gain Measurement Settings Dialog Box ...
Page 102: ...4 30 Remote Control TES Parameters Length Measurement Settings Dialog Box ...
Page 104: ...4 32 Remote Control TES Parameters Normalization Settings Dialog Box ...
Page 106: ...4 34 Remote Control TES Parameters New Normalization Button Dialog Box ...
Page 120: ...4 48 Remote Control Output Parameters ...
Page 158: ...5 38 Maintenance Hewlett Packard Sales and Service Offices ...
Page 170: ...6 12 Installation Installation ...
Page 174: ...7 4 Reference Theory of Operation Figure 7 3 HP 86037B Block Diagram Options 121 and 122 ...
Page 175: ...7 5 Reference Theory of Operation Figure 7 4 The HP 86037B Option 114 block diagram ...
Page 190: ...7 20 Reference System Options ...
Page 191: ...8 Specifications 8 3 Regulatory Information 8 7 Specifications and Regulatory Information ...
Page 204: ...Index 6 Index ...