![HP 8360 B Series User Manual Download Page 383](http://html.mh-extra.com/html/hp/8360-b-series/8360-b-series_user-manual_163548383.webp)
Function Group
Menu Map
Description
Programming Codes
See Also
SWEEP
7
This
lets you set a sweep time for frequency sweeps or power
sweeps. The sweep time range is 10 ms to
but the fastest sweep
time is constrained by the frequency span. The fastest possible sweep
can be determined automatically:
1. Press SWEEP
this reveals the sweep menu keys.
2. Select more
, to scroll to the next page of the sweep menu.
Select
Auto, to set the sweep time to automatic. The
swept signal generator calculates the fastest possible calibrated
sweep time for
any
sweep span.
Whenever you press
the active entry area displays
the current sweep time and whether the sweep time is coupled to
the frequency span (far right hand side displays: AUTO). If the word
AUTO is not displayed then the sweep time auto function is off.
SCPI:
SWEep[:FREQ uency]:TIME <num>[time suffix] or
Analyzer:
ST
Power Sweep
“Power Level and Sweep Time Operation” in Chapter 1
“Programming Typical Measurements” in Chapter 1
Function Group
SWEEP
Menu Map
S-76 Operating and Programming Reference
Summary of Contents for 8360 B Series
Page 363: ...NF N 2 w z P w D I oa 0 i B 6 7 On s5 n 20 a g 9 i T2 ...
Page 406: ...2b Menu Maps Menu Maps 2b 1 ...
Page 407: ...t t m ALC Bandwidth Select Module Sense Low High Auto AUTO Front Rear None ALC MENU ...